Informatica Powercenter Certification Training

One of the top providers of online IT training worldwide is VISWA Online Trainings. To assist beginners and working professionals in achieving their career objectives and taking advantage of our best services, We provide a wide range of courses and online training.

4627 Reviews 4.9
4.7/5

Learners : 1080

Duration :  25 Days

About Course

In the years 1995–1996 in California, Mr. Dillon founded the IT company Informatica. Although Informatica has produced certain technical tools, people frequently refer to it as software when they do so. ETL, data migration, data integration, data virtualization, data masking, data replication, and many other data products are available from Informatica. Enrol today to earn your certification.

Informatica Training Course Syllabus

INTRODUCTION TO DATA WAREHOUSING

✔ Data Warehousing Concepts
✔ Dataware housing (what/Why/How)
✔ Data Modelling(Schemas, FACTS, and DIMENSIONS)
✔ Slowly Changing Dimensions
✔ Metadata

PowerCenter Components and User Interface

✔ PowerCenter Architecture
✔ PowerCenter Client Tools
✔ Lab – Using the Designer and Workflow Manager

Introduction to Power Center Designer

✔ Source Analyzer
✔ Target Designer
✔ Mapping Designer

Power Center Workflow Designer

✔ Workflow Designer
✔ Task developer
✔ Work let Designer

Power Center Workflow Monitor

✔ Job-status
✔ Job session logs

Loading Strategy

✔ Flat file to flat file load
✔ Flat file to database load
✔ Database to database load
✔ Database to flat-file load
✔ XML file to database load
✔ XML file to flat file load

Different Transformations

✔ Source Qualifier
✔ Source Qualifier Join
✔ Source Qualifier Filter
✔ Expression
✔ Connected Stored Procedure
✔ Unconnected Stored Procedure
✔ Sequence Generator
✔ Aggregator
✔ Filter
✔ Lookup
✔ Joiner
✔ Router
✔ Rank
✔ Sorter
✔ Union Transformation
✔ XML Source Qualifier
✔ Using Flat Files as Sources
✔ Using Flat Files as Source and Target
✔ Using XML Files as Source
✔ Reading Data From Multiple Data Bases
✔ Update Strategy
✔ Target Load Plan

Informatica Administration

✔ Installation of Informatica
✔ Installation of Oracle Database
✔ Installation of SQL Server
✔ Creation Repository
✔ Creation of Users
✔ Assigning Privileges to users
✔ Creation of Groups
✔ Adding the Repository to Informatica Repository Manager
✔ Creating Data source Connections
✔ Configuration of SQL server and Oracle Database with Informatica
✔ Scheduling the Workflow

Source Qualifier

✔ Source Qualifier Transformation
✔ Source Pipelines
✔ Source Qualifier Filter and Real-time issues
✔ Source Qualifier SQL over the query

Expression, Filter, File Lists, and Workflow Scheduler

✔ Expression Editor
✔ Filter Transformation
✔ File Lists
✔ Workflow Scheduler
✔ Lab – Load the Customer Staging Table and Real-time issues

Joins, Features, and Techniques

✔ Shortcuts
✔ Lab – Features and Techniques I and Real-time issues

Lookups and Reusable Transformations

✔ Lookup Transformation
Reusable Transformations
Lab A – Load Employee Staging Table
Lab B – Load Date Staging Table and Real-time issues

Debugger

✔ Debugging Mappings
✔ Lab – Using the Debugger

Sequence Generator

✔ Sequence Generator Transformation
✔ Lab – Load Date Dimension Table and Real-time issues

Router, Update Strategy, and Overrides

✔ Router Transformation
✔ Update Strategy Transformation
✔ Expression Default Values
✔ Source Qualifier Override
✔ Target Override
✔ Session Task Mapping Overrides
✔ Lab – Load Employee Dimension Table and Real-time issues

Unconnected Lookup, Parameters, and Variables

✔ Unconnected Lookup Transformation
✔ System Variables
✔ Mapping Parameters and Variables
✔ Lab – Load Sales Fact Table

Sorter, Aggregator, and Self-Join

✔ Sorter Transformation
✔ Aggregator Transformation
✔ Active and Passive Transformations
✔ Data Concatenation
✔ Self -Join
✔ Lab – Reload the Employee Staging Table and Real-time issues

Mapplets

✔ Mapplets
✔ Review and more Activities and Real-time issues

Worklets and More Tasks

✔ Worklets
✔ linkTask
✔ Lab – Load Inventory Fact Table

Live Instructor Based Training With Software
Lifetime access and 24×7 support
Certification Oriented content
Hands-On complete Real-time training
Get a certificate on course completion
Flexible Schedules
Live Recorded Videos Access
Study Material Provided

Informatica Training - Upcoming Batches

7th NOV 2022

8 AM IST

Weekday

Coming Soon

AM IST

Weekday

5th NOV 2022

8 AM IST

Weekend

Coming Soon

AM IST

Weekend

Don't find suitable time ?

CHOOSE YOUR OWN COMFORTABLE LEARNING EXPERIENCE

Live Virtual Training

  • Schedule your sessions at your comfortable timings.
  • Instructor-led training, Real-time projects
  • Certification Guidance.
Preferred

Self-Paced Learning

  • Complete set of live-online training sessions recorded videos.
  • Learn technology at your own pace.
  • Get access for lifetime.

Corporate Training

  • Learn As A Full Day Schedule With Discussions, Exercises,
  • Practical Use Cases
  • Design Your Own Syllabus Based
For Business

Informatica Training FAQ'S

What is Informatica PowerCenter?

Data integration is made possible by ETL solutions like Informatica PowerCenter, which allows data from several sources to be combined into a single dataset. It offers the capability to extract, transform, and load data from various OLTP (Online Transaction Processing) source systems in order to construct enterprise data warehouses. Among the major users of Informatica PowerCenter are the US Air Force, Allianz, Fannie Mae, ING, and Samsung. Without a doubt, it can be used in a variety of ways. The most recent model is Informatica PowerCenter 9.6.0.

Get ahead in your career by learning Informatica through VISWA Online Trainings

Name different types of transformation that are important?

Transformations in Informatica are the repository objects that transform the source data according to the needs of the target system and ensure that the quality of loaded data is maintained. The following transformations are provided by Informatica to accomplish specific functionalities: 

  • Aggregator Transformation: An active transformation used to compute averages and sums (especially across multiple rows or groups).
  • Expression transformation: A passive transformation suitable for calculating values in one row. In addition, conditional statements can be tested before they are written to target tables or other transformations.
  • Filter transformation: An active transformation used for filtering rows in mappings that don’t meet the given condition.
  • Joiner transformation: An active transformation joins data from different sources or from the same location.
  • Lookup transformation: In order to get relevant data, a lookup transformation looks up a source, source qualifier, or target. Results of the lookup are returned to another transformation or the target object. Active Lookup transformation returns more than one row, whereas passive transformation returns only a single row.
An unconnected lookup can have how many input parameters?

Numerous parameters can be included in an unrelated lookup. No matter how many parameters are provided, there will only ever be one return value. For example, you can enter parameters as columns 1, 2, 3, and 4 in an unconnected lookup, but there is only one return value.

What is the role of a repository manager?

A repository manager is an administrative tool used to administer and manage repository folders, objects, groups, etc. A repository manager provides a way to navigate through multiple folders and repositories, as well as manage groups and user permissions.

What is Domain in Informatica?

PowerCenter services are administered and managed by the Informatica Domain. It consists of nodes and services. Each relationship and node are categorized according to the administration requirements into special folders and sub-folders.

Reviews

Quick Links